– Insert condensation drain hose -1- in body opening -2- until it  
is heard to engage.  
Note  
It must be possible to push condensation drain hose -1- onto  
the heater and air conditioning unit connection without tension.  
The condensation drain hose must be fitted securely to the  
condensation drain connection on the tunnel.  
The sealing lip must not be seated loosely on body aperture  
-2-.  
Specified torques  
♦ Centre console; Assembly overview – centre console ⇒ Gen‐  
eral body repairs, interior; Rep. gr. 68 ; Centre console;  
Assembly overview – centre console  
lk  
5.19  
Removing and installing condensation  
drain  
⇒ “5.19.2 Removing and installing condensation drain, right-hand  
drive vehicles”, page 163  
5.19.1  
Removing and installing condensation  
drain, left-hand drive vehicles  
Removing  
– Remove right centre console trim in footwell ⇒ General body  
repairs, interior; Rep. gr. 68 ; Centre console; Assembly over‐  
view - centre console .  
NOTICE  
Risk of damage to airbag control unit. Connectors may corrode  
if moisture enters.  
– After disconnecting, cover or seal off connectors to prevent  
the ingress of moisture.  
161  
theMANUALS.org 5. Front heater and air conditioning unit  
 
Tiguan 2016 ➤ , Tiguan RUS 2017 ➤  
Heating, air conditioner - Edition 06.2017  
– Pull off connector from airbag control unit - J234- -6-.  
– Cover airbag control unit - J234- and connector -6- with wa‐  
terproof sheet.  
– Carefully push floor covering aside and cover it in area under  
condensation drain hose with impermeable sheeting and wa‐  
ter absorbing paper.  
– Carefully pull condensation drain hose off heater and air con‐  
ditioner unit -1- and body -5-.  
Installing  
Install in reverse order of removal. Observe the following:  
– The condensation drain hose can be properly pushed onto  
heater and air conditioner unit -1- to stop in only one position.  
Lug -arrow- on connecting piece must engage in guide -2-.  
If a commercially available cable tie -3- was installed to retain  
the condensation drain -5-, renew it.  
The condensation drain hose must be routed below the wiring  
harness of the airbag control unit - J234- -6- in the figure.  
– Insert condensation drain hose -1- in body opening until it is  
heard to engage.  
162  
Rep. gr.87 - Air conditioning system  
theMANUALS.org  
Tiguan 2016 ➤ , Tiguan RUS 2017 ➤  
Heating, air conditioner - Edition 06.2017  
The condensation drain hose -1- must be properly clipped in  
(pre-tensioned) at the body opening -2-.  
The sealing lip must not be loose on the body aperture.  
The retaining tabs must be fully engaged.  
If the tension is insufficient, seal joint between body and brack‐  
et using, e.g., silicone adhesive sealant ⇒ Electronic parts  
catalogue (ETKA) .  
Note  
Install the condensation drain hose so that it is not twisted or  
pinched.  
When installing floor covering, ensure that the condensation  
drain hose is not pinched by the floor covering.  
If the condensation drain hose is loose on the heater and air  
conditioning unit connection, secure it e.g. with a hose clip to  
prevent it from slipping. Hose clip ⇒ Electronic parts catalogue  
(ETKA) .  
lk  
Specified torques  
♦ Centre console; Assembly overview – centre console ⇒ Gen‐  
eral body repairs, interior; Rep. gr. 68 ; Centre console;  
Assembly overview – centre console  
5.19.2  
Removing and installing condensation  
drain, right-hand drive vehicles  
Removing  
– Remove right centre console trim in footwell ⇒ General body  
repairs, interior; Rep. gr. 68 ; Centre console; Assembly over‐  
view - centre console .  
– Carefully push floor covering aside and cover it in area under  
condensation drain hose with impermeable sheeting and wa‐  
ter absorbing paper.  
– Remove footrest ⇒ General body repairs, interior; Rep. gr.  
70 ; Trims, interior; Removing and installing footrest .  
NOTICE  
Risk of damage to airbag control unit. Connectors may corrode  
if moisture enters.  
– After disconnecting, cover or seal off connectors to prevent  
the ingress of moisture.  
– Pull off connector from airbag control unit - J234- -5-.  
163  
theMANUALS.org 5. Front heater and air conditioning unit  
Tiguan 2016 ➤ , Tiguan RUS 2017 ➤  
Heating, air conditioner - Edition 06.2017  
– Cover airbag control unit - J234- and connector -5- with im‐  
permeable sheeting.  
– Carefully push floor covering aside and cover it in area under  
condensation drain hose with impermeable sheeting and wa‐  
ter absorbing paper.  
– Carefully pull condensation drain hose -3- off heater and air  
conditioning unit -1- and off body -4-.  
Installing  
Install in reverse order of removal. Observe the following:  
The condensation drain hose -3- can be properly pushed onto  
heater and air conditioning unit -1- to stop in only one position.  
Lug -arrow- on connecting piece must engage in guide -2-.  
If a commercially available cable tie was installed to retain the  
condensation drain -3-, renew it.  
The condensation drain hose must be routed below the wiring  
harness of the airbag control unit - J234- -5- in the figure.  
164  
Rep. gr.87 - Air conditioning system  
theMANUALS.org  
Tiguan 2016 ➤ , Tiguan RUS 2017 ➤  
Heating, air conditioner - Edition 06.2017  
The bracket -1- for the condensation drain hose must be prop‐  
erly clipped into the aperture in the body -2- under tension.  
The sealing lip must not be loose on the body aperture.  
The retainer tabs -arrows- must be fully engaged.  
If the tension is insufficient, seal joint between body and brack‐  
et using, e.g., silicone adhesive sealant ⇒ Electronic parts  
catalogue (ETKA) .  
Note  
Install the condensation drain hose so that it is not twisted or  
pinched.  
When installing floor covering, ensure that the condensation  
drain hose is not pinched by the floor covering.  
If the condensation drain hose is loose on the heater and air  
conditioning unit connection, secure it e.g. with a hose clip to  
prevent it from slipping. Hose clip ⇒ Electronic parts catalogue  
(ETKA) .  
lk  
Specified torques  
♦ Centre console; Assembly overview – centre console ⇒ Gen‐  
eral body repairs, interior; Rep. gr. 68 ; Centre console;  
Assembly overview – centre console  
5.20  
Removing and installing baffle plate  
Removal and installation is described in ELSA, see ⇒ General  
body repairs, interior; Rep. gr. 68 ; Compartments/covers; Re‐  
moving and installing footwell cover on front passenger side .  
165  
theMANUALS.org 5. Front heater and air conditioning unit  

Need help?

If after viewing the owner's manual or service manual you still have some unresolved questions about the car VW Tiguan you can write to us using the link below, describing your problem in detail, we try to answer all questions.


Ask your question on the page - Support!